STEICOfloor

Produced and supervised in accordance with EN 13171
Board Designation WF – EN 13171 – T3 – CS(10 \ Y)40 – TR2,5 – AF 100
Edge profile Tongue and grooved 4 sides
Fire class according to EN 13501-1 E
Declared thermal conductivity λD [W/(m*K)] 0,039
Declared thermal resistance RD [(m²*K)/W] 1,0 /1,5
Density [kg/m³] ca. 160
Water vapour diffusion resistance factor μ 5
sd-value [m] 0,2 / 0,3
Specific heat capacity c [J/(kg*K)] 2.100
Minimum compression strength at 10 % deformation σ10 [N/mm²] 0,04
Minimum compression strength [kPa] 40
Tensile strength perpendicular to face [kPa] ≥ 2.5
Declared level of airflow resistance [(kPa*s)/m²] ≥ 100
Raw marterial wood fibre, bond between layers
Waste code (EAK) 030105 / 170201

Product overview

or choose combination

Area of application
Product group