STEICOunderfloor

Produced and supervised according to EN 13986
Porous wood fibre insulating board according to EN 622-4
Board designation EN 622- 4 SB - E1
Edge design square edged
Thermal conductivity l [ W / ( m²*K )] accord. to DIN ISO 10456 Tab. 3 0.07
Bulk density r [kg/m³] ca. 250
Water vapour diffusion resistance factor μ 5
Applied materials wood fibre, aluminium sulphate, dye
Waste code (EAK-Code) 030105 / 170201, Disposal as wood and wood-based material

Technical values according to CEN/TS 16354

3 mm 4 mm 5 mm 7 mm
Punctual conformability PC 1.0 mm 1.6 mm 2.0 mm 2.9 mm
Compressive strength CS > 150 kPa > 150 kPa > 150 kPa > 150 kPa
Compressive creep resistance [kPa] CC > 50 kPa > 50 kPa > 50 kPa > 50 kPa
Dynamic load resistance DL25 > 150.000 cycles > 150.000 cycles > 150.000 cycles > 150.000 cycles
Thermal resistance R 0.043 m²K/W 0.057 m²K/W 0.071 m²K/W 0.100 m²K/W
Water vapour diffusion resistance [m] SD 0.02 0.02 0.03 0.04
Reaction to fire accord. to EN 13501-1 RTF E E E E
Resistance to impact by large diameter ball RLB > 800 mm > 800 mm > 800 mm > 900 mm
Impact sound reduction ISLAM 19 dB 19 dB 19 dB 19 dB
Fulfills minimum requirements of EPLF yes yes yes yes

productoverzicht

toepassingsgebied kiezen
productgroep kiezen