STEICOmulti cover 5
Wear resistant, rain proof vapour control membrane
Wear resistant, rain proof vapour control membrane for external use
- Can be used as temporary covering
- Slip-resistant, excellent walkability even in wet conditions
- Robust and flexible: 3-layer, coated PP nonwoven fabric, mesh reinforced
- Secure membrane bonding with 2 integrated self-adhesive zones
Technical data sheet
Characteristics
Production and designation | EN 13984: 2013 |
Fire class (RTF) according to EN 13501-1 | E |
Area weight [g/cm²] | 150 |
sd value [m] | 5,00 |
Temperature resistance [°C] | -40 / +80 |
Max. tensile force longitudinal [N/5cm] | ≥ 320 |
Max. tensile force transverse [N/5cm] | ≥ 270 |
Elongation at Max. tensile force longitudinal [%] | ≥ 40 |
Elongation at Max. tensile force transverse [%] | ≥ 40 |
Tear resistance longitudinal [N] | ≥ 350 |
Tear resistance transverse [N] | ≥ 300 |
Resistance to water penetration | W1 |
Seepage resistance after artificial ageing | W1 |
Outdoor exposure [weeks] | 12 |
Dimensions
Article number | Length [mm] |
Width [mm] |
Area/roll [m²] | Coverage/pal. net [m²] | Number/pal. [pcs.] |
---|---|---|---|---|---|
359301 | 50000 | 1500 | 75 | 1500,000 | 20 |
Processing STEICOmulti cover 5
- Clean roof surface in advance and free from obstructions (nails and sharp objects)
- Lay the membrane so that the printed side is facing the fitter
- Lay the membrane or sheet parallel to the eaves starting with an overlap of at least 10 cm
- Fix the membrane or sheet in place lolely within the overlap area (e.g. clips)
- Activate the longitudinal self-adhesive areas by removing the protective strip only after the membrane or sheet has been fixed in place
- Overlaps, component joints and penetrations must be made in an airtight manner by means of STEICO system accessories
(Please refer to the product data sheet for detailed information)
Declaration of performance
System Recommendations