STEICOfix

Wood fibre insulation wedge for window sills

Wood fibre insulation wedge for window sills on ventilated facades

  • Reliable protection from wind-driven rain and snow
  • Robust safety for window connections in timber construction
  • Ideal for use in combination with STEICOprotect ETICS
  • Particularly easy to install
  • Available in standard lengths and widths

Technical data sheet pdf

Application area
  • Installation in timber construction or renovations as a second water-bearing level under window sills

Technical Specifications

Tilt 5,00 °
Fire class (RTF) according to EN 13501-1 E
Declared thermal conductivity 0.045 W/(m*K)
Water vapour diffusion resistance factor µ 7
Water pressure resistance in mm water column ≥ 4.000 mm
Outdoor exposure 4 weeks
Compression strength ≥ 200 kPa
Ingredients woodfibre, polyurethane resin, paraffin, membrane

Bonded carbon

During growth, trees absorb carbon dioxide (CO2) and split the molecule into carbon (C) and oxygen (O2). The carbon is bound in the wood. The amount of bound carbon (C) is therefore also referred to as CO2 equivalent (CO2eq). As long as the wood is used in the form of wood products, the carbon remains bound and is removed from the atmosphere.

Biogenic carbon content in the product according to EN 15804+A2

approx. 305  kg CO₂eq/m³

Dimensions

Thickness [mm]

Thickness (drip edge) [mm]

Length [mm]

Width [mm]

Number/pal. [pcs.]

Number/pack. [pcs.]

16 8 1350 100 560 10
20 8 1350 140 560 10
23 8 1350 180 400 10
25 8 1350 200 350 10
30 8 1350 260 240 10

Weight and Packaging

Thickness [mm]

Thickness (drip edge) [mm]

Length [mm]

Width [mm]

Weight/pcs. [kg] Weight/pack. [kg] Packaging/pack. Paper/cardboard (approx.) [kg]
16 8 1350 100 0,8 10,00 0,59
20 8 1350 140 0,9 11,00 0,67
23 8 1350 180 1,0 12,00 0,75
25 8 1350 200 1,2 15,00 0,93
30 8 1350 260 1,5 17,00 1,01
Notes

Storage

  • Store wood fibre boards horizontally, flat and dry
  • Protect from permanent UV exposure

Disposal

Waste cuttings:

  • Waste code according to 2014/955/EU: 03 01 05

Dismantling:

  • Waste code according to 2014/955/EU: 17 02 01

Installation

  • The wood fibre wedge be cut to size using a band saw, circular saw, jigsaw and other wood-cutting tools.
  • To prevent the laminated water-bearing sheet from tearing out, cut on the non-covered side of the wedge

Occupational health and safety

  • HSE guidance on the safe cutting of timber and the management of wood dust should be followed

Certificates quality management

Caption
other abbreviations

pal. Pallet

T&G Tongue and Groove

pac. Packaging

approx. Approximately

SE square edge

Pcs. Pieces