Board designation |
WF – EN 13171 – T4 – DS(70,-)2 – CS(10\Y)100 – TR10 – WS1,0 – AF100 |
Edge profile |
double tongue and groove to all 4 edges |
Fire class according to 13501-1 |
E |
Declared thermal conductivity λD [W/(m*K)] |
0,046 |
Declared thermal resistanceRD [(m²*K)/W] |
1,30 / 1,70 / 2,15 / 2,60 |
Board density [kg/m³] |
ca. 240 |
Water vapour diffusion resistance factor μ |
5 |
sd-Value [m] |
0,3 / 0,4 / 0,5 / 0,6 |
Specific heat capacity [J/(kg*K)] |
2100 |
Minimum compression strength at 10% deformation σ10 [N/mm²] |
0,10 |
Minimum compression strength [ kPa ] |
100 |
Tensile strength perpendicularly to the face [kPa] |
≥ 10 |
Declared level of airflow resistance [(kPa*s)/m²] |
≥ 100 |
Raw materials wood fibre, aluminium sulphate, Parafin, silicate , waterproofing agents, bond between layers |
|
Waste code (EAK) |
030105 / 170201 |