STEICOmulti membra 5
Vapour control layer
Vapour control layer for airtight internal use
- Particularly robust and flexible
- Highly tear-resistant
- Vapour permeable, sd value 5 m
- Suitable for air-injected insulation and insulation batts
- Suitable for sub and top installation when sufficient insulation covering is provided by STEICO wood fibre sarking boards
Characteristics
Production and designation | EN 13984: 2013 |
Fire class (RTF) according to EN 13501-1 | E |
Area weight [g/cm²] | 130 |
sd value [m] | 5,00 |
Temperature resistance [°C] | -40 to +80 |
UV protection in non-installed state | 3 Months |
Max. tensile force longitudinal | 350 |
Max. tensile force transverse | 350 |
Elongation at Max. tensile force longitudinal [%] | 20 |
Elongation at Max. tensile force transverse [%] | 20 |
Tear resistance longitudinal [N] | 270 |
Tear resistance transverse [N] | 270 |
Dimensions
Length [mm] |
Width [mm] |
Area/roll [m²] | Coverage/pal. net [m²] | Number/pal. [pcs.] |
---|---|---|---|---|
50000 | 1500 | 75 | 1500,000 | 20 |
50000 | 3000 | 150 | 3000,000 | 20 |
Processing STEICOmulti membra 5
- Lay the membrane or sheet so that the printed side is facing the fitter
- Lay the sheet parallel or at a right angle to the rafters wirh an overlap of at least 10 cm
- Ensure flush-processed bay insulation. There may be no cavities between the bay insulation and sheet/membrane. Visual check thanks to translucent character
- Fit the membrane or sheet in a tension-free manner and avoid creases
- Overlaps, component joints and penetrations must be made in an airtight manner by means of STEICO system accessories
- Additional mechanical fastening (e.g. battens) must be used immediately after installation to support the weight of the insulation
Processing in case of air-injected insulation:
- The distance between the clips to be used for fixing the vapour barrier in place on the supporting structure is max. 10 cm
- The use of STEICO fibreboard strips or an additional lath along the rafter is recommended as an alternative
- Before the introduction of the air-injected insulation, cross lathing must be arranged with a max. centre distance of 420 mm
- Once the insulation has been injected, seal the injection holes in an airthight manner using STEICOmulti tape P stickers
(Please refer to the product data sheet for detailed information)